PROGATE

PROGATE quick start. Gate control via cell phone: https://topkodas.lt/Downloads/media/Manuals/FAQ/PROGATE_QS_EN.pdf

– Screw the GSM antenna to the antenna connector.
– Insert the SIM card in the SIM card holder.
– Ensure that PIN request function is disabled.
– Ensure that mobile data is enabled if mobile app will be used.
– Connect power supply.
– Connect the module to the computer via mini USB cable

Step by step

• Call PROGATE SIM card’s number from your cell phone
• PROGATE will decline the call
! It is FREE
• The first person called to the module, become system’s administrator
• The phone number will be saved to the memory of the module
• You will receive SMS message from the module

• When you call to the module PROGATE for the first time, your phone number will be stored in the module’s memory automatically.
• This means you can control RELAY output with free short call.

! Calls from different phone number will be rejected

• You will also be able to receive SMS alarm messages.
• The settings can be changed with free SERA2 program.

• Install configuration software SERA2.
• You will find it in: https://www.topkodas.lt/downloads/
• It is possible to select output mode in SERA2> Outputs (PGM)
• Press „Write“ icon in the command line

There is RELAY already integrated in PROGATE. If you can’t use it and If you want to connect RELAY, you have to connect it to I/O (programmable selectable input or output)
I/O could be programmable selectable as input or output in SERA2.
If you use I/O as output, you should programmable disable it as input in “inputs/ burglar alarm zones” window in SERA2

How to add user for remote control purpose: https://topkodas.lt/Downloads/media/Manuals/FAQ/PROGATE_Add_user_for_remote_control.pdf

How to add user via: FREE call, SMS message, FREE mobile APP, FREE SERA2 software

— FREE short call

• Call PROGATE SIM card’s number from your cell phone
• PROGATE will decline the call
! It is FREE
• The first person called to the module, become system’s administrator
• The phone number will be saved to the memory of the module
• You will receive SMS message from the module

— SMS message

Send SMS command:INST000000 004 ID#TEL#OUT#OPT#NAME#
You will see the phone number in SERA2
Just read user’s list in PROGATE

• INST000000 004 ID#TEL#OUT#OPT#NAME#
• 000000 – default installer password
• To enter user‘s telephone number for remote control via short call USER NAME-only
Latin characters is allowed inside SMS
• 004= command code (enter user‘s telephone number for remote control via short call) ID
= user ID number 001-800
• TEL = user‘s telephone number (max 16 digits) without (+) comprised of country code,
operator‘s code and user‘s telephone number.
• the end symbol #;
• OUT= output number, that will be controlled.
• OPT = DIAL function: 0 – disabled 1 – enabled, Sequence from the left to the right
• OPT: 1-ARM/DIARM

— FREE app

Add user via FREE app
You will see the phone number in SERA2
Just read user’s list in PROGATE

If You will use mobile app Mobile data must be enable in SIM card

FREE SeraNova app: https://play.google.com/store/apps/details?id=com.seranova.cloud

— FREE SERA2 software

• It is possible to add user via FREE SERA2 software
• You will find it in https://www.topkodas.lt/downloads/
• Go to SERA2> Users/ Access control> Users window
• Press “Read” in the command line
• Edit configuration
• Press “Write” in the command line

• To start configuration plug – in USB cable or connect remotely

PROGATE: How to edit event SMS text: https://topkodas.lt/Downloads/media/Manuals/FAQ/PROGATE_How_to_edit_event_SMS_text.pdf

•Go to SERA2> Event Summary
•Edit text
•Press „Write“ in the command line

•SERA2> GSM Communications> SMS/ DIAL Reporting
•Unmark
•Press „Write“ in the command line
•SERA2> Users/ Access control> Users
•Edit user name
•Press „Write“ in the command line

How to update firmware via USB?

https://youtu.be/4Yw6NON9o1Y

How to update firmware remotely?

https://youtu.be/8dDBoy7HPFk

How to update SERA2 software and firmware of the module?

https://youtu.be/kC2HoQpbZtQ

 

How to start DS18b20 temperature sensors:

Step by Step: https://youtu.be/CKqObn8bqWU

How to test temperature- humidity monitoring system with free testing, monitoring, diagnostic tool?:

Step by Step: https://youtu.be/N-POEFg_9EE

How to start Wiegand keypad:

Connect Wiegand keypad to the module.

Configurations methods:
Start automatic learning mode via mini USB cable (Sera2 software).
Start automatic learning mode via SMS command INST000000 063 1
Enter Keycard numbers manually via mini USB cable (Sera2 software).
Start automatic learning mode remotely via Sera2 software.

Insert SIM card;
Screw GSM antenna;
Connect power supply;
Connect the module to the computer.

Go to www.topkodas.lt
Find Sera2 software.
Install it in your computer.

Start Sera2 software
Go to Device> Progate

1. Start RFID keycard programming mode automatically via Sera2 software

Step by Step:
Go to Sera2> System Options> General system Options.
Select Dallas 1- Wire Bus
Press “Write”
Press “Start iButton/ RFID/ Phone programming mode”.
Go to Sera2> Users/ Access control window.
Touch RFID keycards to the reader.
RFID keycard number will appear in the list.
Go to System Options> General system Options and
Press “Stop programming” or wait untill it will stop automatically.
Edit setting in the Users/ Access control window.
Press “Write”
Go to RT Testing & Monitoring> Hardware.
Press “Start Monitoring”
Go to RT Testing & Monitoring> Security Alarm Panel/ Access

2. Start RFID keycard programming mode automatically via SMS command INST000000 063 1

Step by Step:
Send SMS message: INST000000 063 1
You will receive the message: iButton/RFID/Caller ID Learning Mode is Swithed ON
Touch RFID keycards to the RFID reader.
Sent the message: INST000000 063 0
You will receive the message: iButton/RFID/Caller ID Learning Mode Stopped

IMPORTANT:

Before activating the RFID learning mode via SMS, the module must have the appropriate System Options> General System Options settings:
Go to Sera2> System Options> General system Options.
Select Dallas 1- Wire Bus
Press “Write”

3. Enter RFID keycard codes manually in Sera2

Step by Step:
Go to Sera2> System Options> General system Options.
Select Dallas 1- Wire Bus
Press “Write”
Go to Sera2> Users/ Access control.
Enter RFID keycard number
Edit other settings
Press “Write”
Go to RT Testing & Monitoring> Hardware
Press “Start Monitoring”
Go to Security Alarm Panel/ Access”
Touch the keycard to the RFID keypad.

4. It is possible to activate iButton/RFID/Caller ID Learning Mode remotely via Sera2 software

Step by Step:
Start Sera2 software
Press “Connect remotely” button
Enter required parameter.
(Default App Key is 123456)
Press “Connect„
Go to Sera2> System Options> General system Options.
Select Dallas 1- Wire Bus
Press “Write”
Press “iButton/RFID/Caller ID Learning Mode”
Touch RFID keycards to the Wiegand keypad”
Press “Stop programming” button
Or wait untill the learning mode will stop automatically

Step by Step: https://youtu.be/F1piuyD3lVQ

How to receive alarm SMS and call after alarms?

Go to www.topkodas.lt
Find Sera2 software.
Install it in your computer.
Start Sera2 software
Go to Device> Progate

Connect the module to the computer.
Connect the power supply.
Go to Sera2> GSM Communication.
Mark Events.
Edit other setting.
Press “Write”.
You will receive alarm events to your mobile phone.

Step by step: https://youtu.be/Pe10WMMuOt8

 

How to start AM2320 temperature- humidity sensors?

Connect AM2320 or AM2302 to the 1W according connection diagram

Insert SIM card;
Screw GSM antenna;
Connect power supply;
Connect the module to the computer

Go to www.topkodas.lt

Find Sera2 software.
Install it in your computer.
Start Sera2 software
Go to Device> Progate

Sensor’s type should be select in the Sera2> System Options> General System Options window. Set Digital I/O D1 to Aosong 1 Wire bus Humidity/ Temperature Sensor AM2302
Write configuration
Read configuration
Go to “Automation/ Sensors” window. The sensor will appear in the list automatically.
Double click on the selected sensor’s line.
Set other parameters of the sensor MIN, MAX values Units etc.

 

Step by step:https://youtu.be/pyG-bk08S_A

 

How to set output pulse counter?

Explanation:

When the Output is activated
it counts defined number of ON pulses and
then returns to OFF state

Set Output pulse counter
Go to SERA> Outputs (PGM)
Out definition> Automation & Access Control
Mode> Pulse Count
Set Pulse ON Time and OFF time
Set Count (the number of pulses)

Output activation methods: App
Call
SMS
iButton
RFID
Keypad
Input value
Sera2> RT Testing & Monitoring> Hardware

Step by step:https://youtu.be/aRUn7KmJdJg

 

How to test the system?

Go to www.topkodas.lt

Find Sera2 software.
Install it in your computer.
Start Sera2 software
Go to Device> Progate

Connect the module to the computer.
Connect the power supply.
Go to Sera2> RT Testing & Monitoring> Hardware.
Press “Start Monitoring”
Go to Sera2> RT Testing & Monitoring> Sensors/ Automation
(Real time sensor values)
Go to Sera2> RT Testing & Monitoring> Event Monitoring
(Alarm events list)

 

GTalarm2

How to start GTalarm2 module?

Step by step: https://youtu.be/ekUeT8NEL0E

How to enter iButton, RFID codes via SERA2, connected via USB.

Step by step: https://youtu.be/rLm7PusHu7g

How to set access schedules?

Step by step: https://youtu.be/BmSKxDGuQLg

How to receive SMS alarms and call after alarms?

Step by step: https://youtu.be/N76NT3ZaNxE

How to set clock synchronization: https://topkodas.lt/Downloads/media/Marketing/Applications/GTalarm2_clock_synchronization.pdf

If you received SMS messages with wrong date/ time, you need to set clock synchronization correctly

You can select clock synchronization via:
GSM modem
(If you will not use mobile app and cloud service)

Cloud Server
(If you will use mobile app)
SIM card must have data available
Insert the SIM card in your smart phone and check is the internet available

Or disable clock synchronization

Clock synchronization via GSM modem
Go to SERA2> System Options> General System Options
Set Clock synchronization via GSM modem
Press “Write” in the command line

Clock synchronization via Cloud server
Go to SERA2> GSM Communication> SERA Cloud Service
Enable SERA Cloud Service

Go to SERA2> System Options> General System Options
Set Clock synchronization via Cloud Server
Press “Write” in the command line

Attention!

If you want to edit existing configuration,
You have to read it (press “Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)

GTCOM2

  1. Start SERA2 software.
  2. Connect the module to the computer
  3. Connect power supply
  4. Go to Sera2> Update (in the command line)
  5. If You want preserve device configuration, mark on the required box
  6. Click Start on the Start FW Update button
  7. Wait until the module will be successfully updated.
  8. Restart the module

GTCOM2 and primary alarm panel synchronization methods:

https://youtu.be/-zo2AMzcwQc

GTCOM2 and primary alarm panel synchronization by Panel’s PGM. Control via FREE App, Short call, SMS:

https://youtu.be/Jp4hf0b4_sQ

GTCOM2 and primary alarm panel synchronization by Panel’s EVENTS VAR.1:

https://youtu.be/dKkdeqnYPO8

GTCOM2 and primary alarm panel synchronization by Panel’s EVENTS VAR.2:

https://youtu.be/gy2KW0ZBCHA

Receive events from primary alarm panel Covert Contact ID codes to SMS text: https://youtu.be/q2erR6-1spw

Receive events from primary alarm panel
Convert Contact ID codes into SMS text

GTCOM2 can simulate PSTN line, receive DTMF Contact ID messages and convert them into readable format as well as
send SMS message to the mobile phone

Attention!
If you want to edit existing configuration,
You have to read it (press “Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)

Enter phone number for alarm SMS
Go to SERA2> GSM Communication> SMS/ DIAL reporting
Enter phone number
Mark alarm events
Press “Write” in the command line

Enter phone number for alarm SMS
Go to SERA2> GSM Communication> SMS/ DIAL reporting
Enter phone number
Mark alarm events
Press “Write” in the command line

Go to SERA2> PSTN CID to SMS Converter> XYZ Contact ID Event Code
Modify Alarm or Restore SMS text
Press “Write” in the command line

Go to SERA2> PSTN CID to SMS Converter> [CCC] User/ Zone Name
Modify Users, Zone names
Press “Write”

Go to Users/ Access control> Users
Enter phone number
Press “Write” in the command line

Receive events from central panel
Settings in Sera2 software

Go to Sera2> GSM Communication> SMS/ DIAL reporting.
Enter phone numbers, mark events, and edit settings.
Go to Sera2>PSTN CID to SMS Converter> [XYZ] Contact ID Event Code.
Edit text in “Alarm SMS Text”, “Restore SMS Text” Select Type.
Go to Sera2>PSTN CID to SMS Converter> [CCC] User/ Zone Name.
Enter User Name
Edit partition name in
Sera2>PSTN CID to SMS Converter> [GG] Group or Partition window
Enter phone numbers for remote control in
Sera2> Users/ Access control window
Press “Write”

Important:

How to set synchronization between primary alarm panel & GTCOM2?

Downloads


GTCOM2 user manual

Events to the Central Monitoring Station
SERA2> GSM Communication> GPRS/IP/TCP/UDP

How to control primary alarm panel from GTCOM2 via iButton keys, short call, SMS, mobile, web app: https://youtu.be/Bs_5JDarxvs

 

How to control primary alarm panel from GTCOM2 Via iButton keys, short call, SMS, mobile, web app?

Prepare the module GTCOM2
Insert SIM card
Screw GSM antenna
Connect iButton reader
Connect the module to the primary panel
Connect the module to the computer via mini USB

Attention!
Disconnect power supply before wiring!

The correct wiring procedure is as follows:
Make sure power is turned off
Make wiring connections to the terminals
Apply power

The module can work with any central panel which has PSTN communicator and
meets Ademco Contact ID data format according to SIA SIA DC-05 standard.
Also Central panel must support phone number dialing using DTMF tones

More information about GTCOM2 and primary alarm panel synchronization:

Downloads


GTCOM2 user manual

Prepare SERA2 software
Install SERA2 software (you will find it in https://www.topkodas.lt/)
Help & Support > Downloads

Before You start, update firmware
Attention!

If you want to edit existing configuration,
You have to read it (press “Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)

Start iButton, phone number entering mode

Go to SERA2> System Options> General System Options
Set 1W (1- wire Bus) to Dallas 1- Wire Bus DS1990A/ DS18b20
Press “Write” in the command line
Press “Start iButton/RFID/ Phone programming mode” button

Go to SERA2> Users/ Access control window
Touch iButton keys to the reader
Go to System Options> General system Options
Press “Stop programming “ button

Enter your phone number in the list
Press “Write”

Go to SERA2> Users/ Access Control window
Modify list
Press “Write” in the command line

Test the system

Go to SERA2> RT Testing & Monitoring> Hardware
Press “Start Monitoring” button
Go to SERA2> RT Testing & Monitoring> Security Alarm Panel/ Access
Touch iButton keys to the reader
You will see the status of the system

Go to SERA2> RT Testing & Monitoring> Security Alarm Panel/ Access
You will see the real time status

ARM/ DISARM with SMS messages
User phone number must be the SERA2> Users/ Access control list

ARM/ DISARM with SMS
USER – command from user commands list
123456 – user’s password (default)
Space character
030- command code Change security system’s mode (ARM/DISARM/STAY/SLEEP
Space character
1- ARM

Change security system’s mode (ARM/DISARM/STAY/SLEEP)
030= command code (Change security system’s mode (ARM/DISARM/STAY/SLEEP)
ST = Security system mode 0-DISARM, 1-ARM, 2-STAY, 3-SLEEP

USER123456˽030˽ST

USER – command from user commands list
123456 – user’s password (default)
˽ – Space character
030- command code
˽ – Space character
ST – Configuration array

Change security system’s mode (ARM/DISARM/STAY/SLEEP)
030= command code (Change security system’s mode (ARM/DISARM/STAY/SLEEP)
ST = Security system mode 0-DISARM, 1-ARM, 2-STAY, 3-SLEEP

Enter user phone number in the Sera2> Users/ Access control list

How to install Android app?
Go to https://play.google.com/store/apps/details?id=com.seranova.cloud

How to add new system in app

To the top right corner, near the user icon, press New system> Add new system
Default App Key: 123456
Default User Access Code: 123456
Go to SERA2> System Options> General System Options
IMEI: Sera2> System options> System info

Control primary alarm panel from GTCOM2

More information about GTCOM2 and primary alarm panel synchronization:

Downloads

ARM/ DISARM methods:

Touch iButton keys to the reader
Send SMS to the module
Call to the module
ARM/ DISARM via mobile, web app

How to set temperature- humidity sensor: https://youtu.be/pRz8jor8Yw4

Go to SERA2> System Options> General System Options
Set 1W (1- Wire Bus) to Aosong 1- Wire Bus HumidityTemperature…
Press “Write” in the command line
Press “Read” in the command line

Press “Read”

Go to SERA2> Automation/ Sensors
You will see the connected sensor in the list
Double click on the selected line

Edit settings
Press “Write” in the command line

Alarms to your mobile phone

Go to SERA2> GSM Communications> SMS/ Dial reporting
Enter phone number
Mark alarm events
Press “Write” in the command line

Go to SERA2> GSM Communication> Custom SMS Text
Edit SMS text
Press “Write” in the command line

Test the system

Go to SERA2> RT Testing & Monitoring> Hardware
Press “Start Monitoring”

Go to SERA2> RT Testing & Monitoring> Sensors/ Automation
You will see the real time sensor values

Go to SERA2> RT Testing & Monitoring> Event Monitoring
You will see Events list

Read Events Log

Go to SERA2> Events Log
Press “Read Event Log” button

How to set temperature sensors DS18b20. Programmable thermostat. Up to 32 sensors: https://youtu.be/VTAiMp78V1Q

Prepare the module GTCOM2

Insert SIM card
Screw GSM antenna
Connect the sensor to the module
Connect power supply
Connect the module to the computer via mini USB

Attention!

Disconnect power supply before wiring!

The correct wiring procedure is as follows:
Make sure power is turned off
Make wiring connections to the terminals
Apply power

Do not change polarity!
It will damage the sensor

It is possible to connect up to 32 temperature sensors DS18b20

Prepare SERA2 software
Install SERA2 software (you will find it in https://www.topkodas.lt/)
Help & Support > Downloads

Before You start, update firmware

Attention!
If you want to edit existing configuration,
You have to read it (press “Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)

Go to SERA2> System Options> General System Options
Set 1W (1- Wire Bus) to Dallas 1-Wire Bus DS1990A/ DS18b20
Press “Write” in the command line
Press “Read” in the command line

Press “Read”

Go to SERA2> Automation/ Sensors
You will see the connected sensor in the list
Double click on the selected line

Edit settings
Press “Write” in the command line

Alarms to your mobile phone
Go to SERA2> GSM Communications> SMS/ Dial reporting
Enter phone number
Mark alarm events
Press “Write” in the command line

Go to SERA2> GSM Communication> Custom SMS Text
Edit SMS text
Press “Write” in the command line

Test the system

Go to SERA2> RT Testing & Monitoring> Hardware
Press “Start Monitoring”

Go to SERA2> RT Testing & Monitoring> Sensors/ Automation
You will see the real time sensor values

Go to SERA2> RT Testing & Monitoring> Event Monitoring
You will see Events list

Read events log

Go to SERA2> Events Log
Press “Read Event Log” button

How to set clock synchronization: https://topkodas.lt/Downloads/media/Marketing/Applications/GTCOM2_clock_synchronization.pdf

How to set clock synchronization?

If you received SMS messages with wrong date/ time,
you need to set clock synchronization correctly

You can select clock synchronization via:
GSM modem
(If you will not use mobile app and cloud service)

Cloud Server
(If you will use mobile app)
SIM card must have data available
Insert the SIM card in your smart phone and check is the internet available

Or disable clock synchronization

Clock synchronization via GSM modem
Go to SERA2> System Options> General System Options
Set Clock synchronization via GSM modem
Press “Write” in the command line

Clock synchronization via Cloud server
Go to SERA2> GSM Communication> SERA Cloud Service
Enable SERA Cloud Service

Go to SERA2> System Options> General System Options
Set Clock synchronization via Cloud Server
Press “Write” in the command line

Attention!
If you want to edit existing configuration,
You have to read it (press “Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)

GTM1

How to set analog current sensor? 4-20mA input. SMS alarms: https://youtu.be/jj1iWeHid8A

How to activate output when programmed level is reached?: https://youtu.be/zaNmQGYxfQU

 

Attention!
Disconnect power supply before wiring!

The correct wiring procedure is as follows:
Make sure power is turned off;
Make wiring connections to the terminals;
Apply power.

Power supply
DC 10-30V
AC 12-24V
Max 0.5A

Prepare the module GTM1
Insert SIM card
Screw GSM antenna

Connect temperature- humidity sensor
AM2320 or AM2302 to the 1W
according connection diagram.

Connect the module to the computer via mini USB cable
Connect the power supply.
Start free configuration program SERA2
You will find it in https://www.topkodas.lt/ website
HELP & SUPPORT> Downloads

Go to SERA2> System Options> General System Options window.
Set 1W (1-Wire Bus)> Aosong 1 Wire bus Humidity/ Temperature Sensor AM2302…
Press “Write” in the command line
Press “Read” in the command line

Go to SERA2> Automation/ Sensors window.
The sensor will appear in the list automatically.
Double click on the selected sensor’s line.

Set other parameters of the sensor MIN, MAX values Units etc.
Press “Write” in the command line

You can set:
trigger conditions (“Min”, “Max” and “Hys.”) and wanted action
Hysteresis (“Hys”) is used to prevent from excessively triggering when the value fluctuates around the trigger point

How to set & test cellular temperature monitoring, alarm, control, automation system: https://youtu.be/NzZOqH–RZM

Attention!
Disconnect power supply before wiring!

The correct wiring procedure is as follows:
Make sure power is turned off;
Make wiring connections to the terminals;
Apply power.

Prepare the module GTM1

Insert SIM card
Screw GSM antenna
Connect temperature sensor DS18b20
to the 1W according connection diagram.

DS18b20 sensor

Red wire to +5V
Yellow wire to 1W
Black wire to COM

The DS18B20 digital thermometer provides

12-bit Celsius temperature measurements.
The DS18B20 communicates over a 1-Wire
Each DS18B20 has a unique 64-bit serial code,
which allows multiple DS18B20s to function on the same 1-Wire bus

It is possible to connect up to 32 temperature sensors DS18b20

DS18b20 connection with A long distance UTP or FTP cable
If you need to connect more sensors to 1W
Connect them as a star or serial.
Each line should be separated by 82-120 Ohm resistor

Connect the module to the computer via mini USB cable
Connect the power supply.
Start free configuration program SERA2
You will find it in https://www.topkodas.lt/ website
HELP & SUPPORT> Downloads

Go to SERA2> System Options> General System Options window.
Set 1W (1-Wire Bus)> Dallas 1-Wire Bus DS18b20…
Press “Write” in the command line
Press “Read” in the command line

Go to SERA2> Automation/ Sensors window.
The sensor will appear in the list automatically.
Double click on the selected sensor’s line.

Set other parameters of the sensor MIN, MAX, alarm values etc.
Press “Write” in the command line

You can set:

trigger conditions (“Min”, “Max” and “Hys.”) and
wanted action.

SMS alarm event values

Hysteresis (“Hys”) is used to prevent from
excessively triggering when
the value fluctuates around the trigger point

Go to SERA2> RT Testing & Monitoring > Hardware
Press “Start Monitoring”

Go to RT Testing & Monitoring> Sensors Automation

Go to SERA2> RT Testing & Monitoring> Event Monitoring

Read Events Log

Go to SERA2> Events Log
Press “Read Event Log” button

Alarm SMS

Go to SERA2> GSM Communication > SMS/ DIAL reporting
Enter your phone number
Mark alarm events
Press “Write” in the command line

How to set How to set AC LOSS & LOW BATTERY ALARMS: https://youtu.be/efFf5vLXXxA

Prepare the module GTM1

Insert SIM card
Screw GSM antenna

How to configure the module GTM1 for AC failure, restore function

Connect the module to the computer via mini USB cable
Start free configuration program Sera2
You will find it in https://www.topkodas.lt/ website
HELP & SUPPORT> Downloads

Go to SERA2> Inputs/ Burglar Alarm Zones
Double click on the 4th row

Enter the required parameters.
Press “Write” icon
(in the command line.)

Zone speed:
If needed to eliminate short AC grid disturbance Set min 60000ms It means if AC loss time is more than 1 min
AC loss event will be detected

Event repeat timeout:
To avoid repeatable AC loss event generation Event repeat timeout Could be set to 600s &
Max alarm count could be set to 1. It means only one “AC loss” event Will be generated in 10 min

SMS alarms
SERA2> GSM Communication> SMS/ DIAL reporting
SERA2> System Options> System Fault/ Troubles
SERA2> GSM Communication> Custom SMS text and edit text

How to set & test security, alarm system?. Alarms to mobile & to central monitoring station:

VIDEO: https://youtu.be/K61orKZ8R-o

PDF: https://topkodas.lt/Downloads/media/Marketing/Applications/APPLICATION_GTM1_Security.pdf

How to control primary security system with GTM1 : https://youtu.be/t3VZmp_wmUs

How to set clock synchronization?

If you received SMS messages with wrong date/ time,
you need to set clock synchronization correctly

You can select clock synchronization via:
GSM modem
(If you will not use mobile app and cloud service)

Cloud Server
(If you will use mobile app)
SIM card must have data available
Insert the SIM card in your smart phone and check is the internet available

Or disable clock synchronization
Clock synchronization via GSM modem
Go to SERA2> System Options> General System Options
Set Clock synchronization via GSM modem
Press “Write” in the command line

Clock synchronization via Cloud server
Go to SERA2> GSM Communication> SERA Cloud Service
Enable SERA Cloud Service

Go to SERA2> System Options> General System Options
Set Clock synchronization via Cloud Server
Press “Write” in the command line

Attention!
If you want to edit existing configuration,
You have to read it (press “Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)